Raymarine NMEA Multiplexer Especificações Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 44
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
18
Menu
The menu contains two sub-menus: File and Tools. The File menu contains the following options
to choose from:
Start Log… Start writing NMEA data to a log file. A log file is a plain text file and
can later be opened by any text editor to examine the data. A log file
can be a useful tool for diagnostic purposes and is often requested by
us for support. If you enter a new filename in the file dialog window, a
new log file is created. If you choose an existing file, this file will be
overwritten with new data. The Log counter on the status bar will show
the number of NMEA sentences that are currently written to the log file.
Timed Log… Start writing to a log file with the addition of a time stamp at the
beginning of each NMEA sentence.
Stop Log Stop writing NMEA data to the current log file and close that file.
Load Configuration… Load a previously saved configuration file into the multiplexer. The
current configuration will be overwritten. A configuration file stores all
settings made with MPX-Config. See the Technical Reference section for
a description of this file format.
Save Configuration Save the current configuration to a file. If a file was previously opened,
that file will be overwritten. If no file has been opened before, you will
be prompted for a file name. The name of the currently loaded
configuration file is shown on the status bar.
Save Configuration As… Save the current configuration to a new file.
Update Firmware… Load new firmware into the multiplexer. From time to time, new
features are developed for the multiplexer or bugs are fixed. New
firmware image files will then be made available through our website.
These image files can be downloaded to your computer and loaded into
the multiplexer with this option. This option will only be visible when
your multiplexer supports firmware updates. This is the case from
firmware version 3.00 and up. Multiplexers containing lower firmware
versions need to be returned to our factory for an update.
Exit This option exits MPX-Config.
The Tools menu contains the following options to choose from:
Clear Screen Clear the data area on the screen. New sentences will be displayed
from the top.
No Scroll Normally, incoming NMEA sentences are displayed from the top down
and when the bottom of the data area has been reached, all sentences
are scrolled up one line before the new one is show. When No Scroll is
activated, a list of incoming NMEA sentences will be displayed that will
be refreshed constantly when new similar sentences are received. A
scroll bar will appear when the list grows beyond the length of the data
area. This feature allows you to closely examine the types of sentences
that are received from the connected instruments. Any proprietary
NMEA sentences that are generated by the multiplexer are also listed.
The can be recognised by the firsts four characters, which are ‘$PSMD’.
Show Statistics This option opens a new window that will be displayed on top of the
MPX-Config window. This window show bars that indicate how much
NMEA data is stored in the input queues. This is a useful option for
diagnosing data congestion and overflow situations as mentioned in
paragraph ‘Data Throughput’. A queue that is filled constantly can lead
to unacceptable delays in data transfer.
About Show a window with version information.
Vista de página 17
1 2 ... 13 14 15 16 17 18 19 20 21 22 23 ... 43 44

Comentários a estes Manuais

Sem comentários